Dual-Source Air-Cooled Chiller

Dual-Source Air-Cooled Chiller

Integrated mechanical refrigeration and free cooling in one unit

TB-CWM1750C-800F with oil-free air-bearing compressors and gravity heat-pipe cooling

The TAYBO TB-CWM1750C-800F dual-source chiller is designed for data center cooling. It integrates oil-free air-bearing compressor mechanical refrigeration with gravity heat-pipe free cooling in a single unit. The system selects the operating mode based on outdoor conditions—providing mechanical cooling when required and using free cooling to cut compressor runtime when conditions allow. The unit combines a V-coil heat exchanger, axial fans, compressors, and controls in one package to simplify equipment integration for integrated cooling plants and data center cooling systems.

Typical Integration Scope

Mechanical refrigeration mode

Mechanical refrigeration mode

Reference cooling capacity 1,750 kW; reference input power 440 kW; calculated COP about 3.98.

Free-cooling mode

Free-cooling mode

When ambient conditions allow, refrigerant transfers heat to outdoor air by gravity circulation with compressors off. At a temperature difference ΔT of at least 15°C, free-cooling rated capacity is 800 kW, helping cut mechanical cooling runtime and energy use.

Key Engineering Inputs

01

Oil-free air-bearing technology

During normal operation the rotating shaft is supported by an air film—no bearing lubricant and no bearing contact.

02

Mechanical refrigeration and free cooling in one unit

Both cooling modes are integrated in a single unit and can run accordi

03

Gravity heat-pipe free cooling

Under suitable conditions, heat is rejected through refrigerant gravity circulation with compressors shut down.

04

Integrated equipment design

V-coil heat exchanger, axial fans, compressors, and controls in a coordinated one-piece layout.

05

Convenient system connections

DN250 bottom water connections, RS485 communications, and IP55 rating for easy tie-in to project cooling and monitoring systems.

Product Value

Two operating modes

Mechanical refrigeration and free cooling in a single unit

Lower runtime and energy use

Cut compressor runtime and cooling energy when ambient conditions allow

Fewer system requirements

Oil-free air-bearing design needs no bearing lubricant and reduces related lubrication system needs

Integrated package

One-piece layout simplifies equipment integration and supports integrated cooling plant arrangements

Easy system tie-in

Standard water and communication interfaces simplify connection to project cooling and monitoring systems